2-Pole Automatic Transfer Switch (ATS) – For Single-Phase Critical Loads
Ensure continuous power for essential single-phase equipment with our compact 2-Pole Automatic Transfer Switch (ATS). Designed for smaller backup systems, it automatically and seamlessly transfers the load between a primary (Utility) and secondary (Generator) power source upon detecting a failure. Ideal for safeguarding servers, telecom gear, lighting circuits, and other vital 120/240V AC loads from downtime.
Bullet Points:
-
Fully Automatic: Monitors primary power and initiates switch to backup within seconds.
-
Compact & Modular: Space-saving design for panel or standalone enclosure mounting.
-
Reliable Switching: High-performance contactor or solid-state switching mechanism.
-
Intuitive Controls: LED status indicators, test switch, and adjustable time delays.
-
Wide Compatibility: Works with most single-phase generators and inverters.
Main technical parameters
| Specification | Model of circuit breaker | Frame size current (A) | Rated operation current (A) | Breaking current (kA) | Rated service voltage (V) | Insulation voltage (V) | Frequency (Hz) | Transfer time | Rated operation voltage of controller (V) | Mechanical life |
| WCQ2A(1)-63/3 | WCM1 series | 63 | 6, 10, 20, 25, 32, 40, 50, 63 | Take specific type of circuit breaker specification for reference | 400 | No flash, no spark-over within 1min 2500V | 50~60 | 0-30 seconds adjustable | AC230V | 5000 times |
| WCQ2A(1)-63/4 | ||||||||||
| WCQ2A(1)-100/3 | 100 | 10, 20, 25, 32, 40, 50, 63, 80, 100 | ||||||||
| WCQ2A(1)-100/4 | ||||||||||
| WCQ2A(1)-225/3 | 225 | 100, 125, 140, 160, 180, 200, 225 | ||||||||
| WCQ2A(1)-225/4 | ||||||||||
| WCQ2A(1)-400/3 | 400 | 200, 250, 315, 400 | ||||||||
| WCQ2A(1)-400/4 | ||||||||||
| WCQ2A(1)-630/3 | 630 | 250, 315, 400, 500, 630 | ||||||||
| WCQ2A(1)-630/4 | ||||||||||
| WCQ2A(1)-800/3 | 800 | 630, 700, 800 | ||||||||
| WCQ2A(1)-800/4 | ||||||||||
| WCQ2A(1)-1250/3 | 2000 | 1250, 1600, 2000 | ||||||||
| WCQ2A(1)-2000/3 |


Key Features & Benefits:
-
Seamless, Automatic Operation:
-
Feature: An integrated microprocessor controller constantly monitors voltage and frequency on the primary source. Upon detecting an outage or deviation beyond set parameters, it sends a start signal to the generator and executes the transfer once backup power is stable and within tolerance.
-
Benefit: Eliminates downtime for critical loads. The transition is fast enough to keep most sensitive electronics running without disruption, protecting data and processes.
-
-
Robust & Adaptive Control Logic:
-
Feature: Programmable time delays including engine start delay, transfer delay (to allow generator stabilization), and retransfer delay (to ensure utility power is stable). Features source priority selection (Utility or Generator preferred).
-
Benefit: Protects the generator from short-cycling and ensures clean, stable power is delivered to the load, extending equipment life for both the ATS and the generator.
-
-
High-Reliability Switching Component:
-
Feature: Utilizes a high-grade, electrically-held contactor or a zero-crossing solid-state relay as the switching element, designed for thousands of reliable operations under load.
-
Benefit: Provides dependable performance and long electrical life. The chosen mechanism ensures positive isolation between sources to prevent backfeed, a critical safety function.
-
-
Compact Design for Easy Integration:
-
Feature: Engineered with a space-optimized footprint, available in open-frame models for panel builders or in self-contained enclosures (NEMA 1 or 3R).
-
Benefit: Fits into tight spaces in electrical cabinets or on walls, simplifying installation in both new constructions and retrofit projects for critical circuits.
-
-
User-Friendly Interface & Diagnostics:
-
Feature: Front-panel interface with clear LED indicators for power source status and alarms. Includes a manual test switch to simulate an outage and verify system operation without disrupting the actual power.
-
Benefit: Simplifies testing and troubleshooting. Provides instant visual confirmation of system status, ensuring readiness and simplifying maintenance.
-
Technical Specifications:
| Parameter | Specification |
|---|---|
| Type | Automatic Transfer Switch (ATS) |
| Poles | 2 |
| Rated Operational Current (Ie) | Common ratings: 30A, 63A, 100A, 125A |
| Rated Voltage (Ue) | 120/240V AC, Single Phase, 50/60Hz |
| Withstand & Closing Rating | Withstand (Icw): [e.g., 10kA] for 1 sec. |
| Control Voltage | 12/24 VDC (from Gen) or 120/240 VAC |
| Transfer Time | Adjustable, typically 1-3 seconds after backup is available |
| Switching Device | Contactor or Solid-State Relay (SSR) |
| Enclosure Options | Open Frame, NEMA 1 (Indoor), NEMA 3R (Outdoor) |
| Controller Features | Programmable Delays, Voltage/Frequency Monitoring, Self-Test |
| Standards Compliance | UL 1008, IEC 60947-6-1 (Applicable sections) |
Ideal Applications:
-
IT & Telecom: Server racks, network switches, communication cabinets, data loggers.
-
Security & Life Safety: Access control systems, surveillance DVRs/NVRs, fire alarm panels, emergency lighting control.
-
Commercial/Retail: Point-of-Sale (POS) systems, refrigeration controls, critical signage.
-
Industrial Control: PLCs, instrumentation, process control panels for single-phase equipment.
-
Medical: Diagnostic equipment, dental chairs, laboratory analyzers with single-phase input.
Value Proposition:
-
Ensure Uptime: Automatically maintain power to equipment that cannot afford to stop, protecting revenue and safety.
-
Reduce Operational Risk: Eliminate human error and delay associated with manual transfer methods.
-
Enhance System Protection: Intelligent delays and monitoring protect both the backup generator and the connected loads.
-
Simplify Compliance: Meets code requirements for emergency and legally required standby systems (per NFPA 70, NEC).
Installation & Support:
-
Professional Installation Required: Must be installed and configured by a qualified electrician.
-
Warranty: Backed by a [e.g., 3-Year or 5-Year] Limited Warranty.
-
Documentation: Comprehensive installation, programming, and wiring guides provided.
Ordering Information:
-
Specify: Current Rating (Amps), Enclosure Type, Control Voltage Preference.
-
Optional Accessories: Communication modules (for remote monitoring), auxiliary contacts for signaling.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Reviews
There are no reviews yet.