{"id":29456,"date":"2025-12-05T07:09:40","date_gmt":"2025-12-05T07:09:40","guid":{"rendered":"https:\/\/swgct.net\/?post_type=product&#038;p=29456"},"modified":"2025-12-05T07:09:40","modified_gmt":"2025-12-05T07:09:40","slug":"anti-harmonic-smart-capacitor","status":"publish","type":"product","link":"https:\/\/swgct.net\/de\/produkt\/anti-harmonic-smart-capacitor\/","title":{"rendered":"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids"},"content":{"rendered":"<p class=\"ds-markdown-paragraph\"><strong>Introduction:<\/strong><br \/>\nIn today&#8217;s industrial facilities, the proliferation of non-linear loads (VFDs, SMPS, LED lighting) generates harmonics that degrade power quality and pose a severe risk to standard capacitor banks\u2014causing resonance, overloading, and premature failure. Our Anti-Harmonic Smart Capacitor is the engineered solution. It combines a\u00a0<strong>precision-matched detuned reactor<\/strong>\u00a0with a\u00a0<strong>long-life metallized film capacitor<\/strong>\u00a0and an\u00a0<strong>intelligent controller<\/strong>\u00a0into a single, robust unit. This design not only\u00a0<strong>safely corrects power factor<\/strong>\u00a0in distorted environments but also actively\u00a0<strong>suppresses system resonance<\/strong>, delivering reliable performance, maximizing energy savings, and protecting your electrical infrastructure.<\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Key Features &amp; Benefits:<\/strong><\/p>\n<ol start=\"1\">\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Built-in Harmonic Protection &amp; Resonance Suppression:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Feature:<\/strong>\u00a0Integrated\u00a0<strong>detuned reactor<\/strong>\u00a0(typically 7% for 5th\/7th harmonic mitigation or 14% for broader protection). This creates a series-resonant frequency below the lowest dominant harmonic, acting as a high impedance path.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Benefit:<\/strong>\u00a0<strong>Prevents dangerous parallel resonance<\/strong>\u00a0with network inductance, drastically reducing harmonic current flow into the capacitor. This eliminates overheating and\u00a0<strong>extends capacitor lifespan by up to 3-5x<\/strong>\u00a0compared to standard units in harsh environments.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Advanced Intelligence for Optimal Performance:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Feature:<\/strong>\u00a0Onboard 16\/32-bit microprocessor with\u00a0<strong>adaptive control algorithms<\/strong>. Features include: automatic power factor target setting, cyclic switching (first-on-last-off), phase-unbalance compensation, and comprehensive self-diagnostics.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Benefit:<\/strong>\u00a0Ensures\u00a0<strong>precise, dynamic compensation<\/strong>\u00a0with minimal switching operations, reducing wear and preventing over-compensation. Simplifies setup and optimizes system efficiency autonomously.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Robust, All-in-One Modular Design:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Feature:<\/strong>\u00a0Factory-tuned and pre-wired reactor-capacitor module with integrated intelligent switch (thyristor or high-performance contactor) and protection devices in a compact, ventilated enclosure.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Benefit:<\/strong>\u00a0<strong>Slashes installation time and costs<\/strong>\u00a0by up to 60%. Enables modular, plug-and-play expansion. Offers superior reliability over traditional discrete component assemblies.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Comprehensive Multi-Layer Safety &amp; Protection:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Feature:<\/strong>\u00a0Full suite of protections:\u00a0<strong>Internal damping resistors<\/strong>,\u00a0<strong>special HRC fuses<\/strong>,\u00a0<strong>over-temperature sensor<\/strong>, over-voltage\/current protection, and\u00a0<strong>zero-voltage switching<\/strong>\u00a0capability.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Benefit:<\/strong>\u00a0Provides\u00a0<strong>fail-safe operation<\/strong>, minimizes inrush currents, and prevents catastrophic failures. Ensures personnel safety and protects downstream equipment.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Operational Transparency &amp; Communication:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Feature:<\/strong>\u00a0Clear\u00a0<strong>LCD\/HMI interface<\/strong>\u00a0displaying real-time data: PF, kVAr, V, I, kW, THDv%, THDi%, temperature, and fault history. Optional\u00a0<strong>RS485 communication<\/strong>\u00a0with Modbus RTU protocol.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Benefit:<\/strong>\u00a0Enables\u00a0<strong>instant health monitoring<\/strong>\u00a0and seamless integration into SCADA, BMS, or energy management systems for centralized control and data logging.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p class=\"ds-markdown-paragraph\"><strong>Technical Specifications:<\/strong><\/p>\n<div class=\"ds-scroll-area _1210dd7 c03cafe9\">\n<div class=\"ds-scroll-area__gutters\">\n<div class=\"ds-scroll-area__horizontal-gutter\"><\/div>\n<div class=\"ds-scroll-area__vertical-gutter\"><\/div>\n<\/div>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rated Voltage<\/strong><\/td>\n<td>400V \/ 480V AC, 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Capacitance Tolerance<\/strong><\/td>\n<td>-5% to +10%<\/td>\n<\/tr>\n<tr>\n<td><strong>Reactive Power Output (Per Step)<\/strong><\/td>\n<td>5, 10, 15, 20, 25, 30, 40, 50 kVAr (Standard)<\/td>\n<\/tr>\n<tr>\n<td><strong>Detuning Reactor Impedance<\/strong><\/td>\n<td>5.67%, 7%, 14% (Customizable)<\/td>\n<\/tr>\n<tr>\n<td><strong>Switching Device<\/strong><\/td>\n<td>Thyristor (Zero-Crossing) or High-Performance Contactor<\/td>\n<\/tr>\n<tr>\n<td><strong>Protection<\/strong><\/td>\n<td>Over-temperature, Over-voltage, Over-current, Internal Fuse<\/td>\n<\/tr>\n<tr>\n<td><strong>Control Logic<\/strong><\/td>\n<td>PF Target, Reactive Power, Time Schedule<\/td>\n<\/tr>\n<tr>\n<td><strong>Display &amp; Interface<\/strong><\/td>\n<td>LCD with Keypad, LED Indicators<\/td>\n<\/tr>\n<tr>\n<td><strong>Communication<\/strong><\/td>\n<td>RS485, Modbus RTU (Standard)<\/td>\n<\/tr>\n<tr>\n<td><strong>Ambient Temperature<\/strong><\/td>\n<td>-25\u00b0C to +55\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Standards<\/strong><\/td>\n<td>IEC 60831-1\/2, GB\/T 22582, CE, RoHS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong>Ideal Applications:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Industrial Manufacturing:<\/strong>\u00a0Plants with welding machines, induction furnaces, large VFDs, and CNC machinery.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Commercial Buildings:<\/strong>\u00a0Data centers, hospitals, shopping malls, and offices with dense switching-mode power supplies and LED lighting.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Renewable Energy Sites:<\/strong>\u00a0Solar\/Wind inverter stations requiring grid-side power factor compliance.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Water &amp; Wastewater Treatment:<\/strong>\u00a0Facilities with large pump drives and aeration blowers.<\/p>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><strong>Value Proposition:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Maximize Energy Savings:<\/strong>\u00a0Achieve and maintain a target power factor (e.g., 0.95-0.99) to eliminate utility penalties and reduce I\u00b2R losses.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Ensure System Reliability:<\/strong>\u00a0Eliminate capacitor failures caused by harmonics, reducing unplanned downtime and maintenance costs.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Future-Proof Investment:<\/strong>\u00a0Intelligent design adapts to changing load patterns and provides data for energy audits.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Simplify Compliance:<\/strong>\u00a0Helps meet IEEE 519 or similar standards for harmonic current distortion at the point of common coupling (PCC).<\/p>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><strong>Installation &amp; Service:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Design:<\/strong>\u00a0Our engineering team provides free system analysis and sizing support.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Installation:<\/strong>\u00a0Modular design allows for quick cabinet installation. Clear phase and terminal labeling simplifies wiring.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Warranty &amp; Support:<\/strong>\u00a0Backed by a [e.g., 3 to 5-Year] warranty, with global technical support and spare parts availability.<\/p>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><strong>Ordering Information:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Specify:\u00a0<strong>System Voltage, Required kVAr per step, Detuning Impedance (%), Switching Type (Thyristor\/Contactor), and Communication needs.<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Custom Configurations<\/strong>\u00a0available for specific harmonic spectra or extreme environmental conditions.<\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p class=\"ds-markdown-paragraph\">Our Anti-Harmonic Smart Capacitor is an advanced power correction device designed to operate reliably in harmonic-rich environments. It integrates a detuned reactor (e.g., 7% or 14% impedance) with an intelligent switching module, providing safe, automatic reactive power compensation while protecting itself from harmonic overloads. This all-in-one solution improves power factor, reduces energy losses, and ensures stable performance in industrial and commercial applications.<\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Bullet Points:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Harmonic Immunity:<\/strong>\u00a0Built-in detuning reactor prevents resonance and protects capacitor from overheating due to harmonics.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Intelligent Control:<\/strong>\u00a0Embedded microprocessor for automatic PF correction, phase-unbalance detection, and self-protection.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Compact &amp; Easy:<\/strong>\u00a0All-in-one design simplifies installation, wiring, and system expansion.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Enhanced Safety:<\/strong>\u00a0Internal fuses, over-temperature, and over-voltage protection ensure long operational life.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Real-Time Data:<\/strong>\u00a0LCD display shows PF, voltage, current, harmonics (THD), and status.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":29458,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[96],"product_tag":[106],"class_list":{"0":"post-29456","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-harmonic-resistant-intelligent-capacitor","7":"product_tag-harmonic-resistant-intelligent-capacitor","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids - Swgct<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/swgct.net\/de\/produkt\/anti-harmonic-smart-capacitor\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids\" \/>\n<meta property=\"og:description\" content=\"Our Anti-Harmonic Smart Capacitor is an advanced power correction device designed to operate reliably in harmonic-rich environments. It integrates a detuned reactor (e.g., 7% or 14% impedance) with an intelligent switching module, providing safe, automatic reactive power compensation while protecting itself from harmonic overloads. This all-in-one solution improves power factor, reduces energy losses, and ensures stable performance in industrial and commercial applications. Bullet Points:     Harmonic Immunity:\u00a0Built-in detuning reactor prevents resonance and protects capacitor from overheating due to harmonics.    Intelligent Control:\u00a0Embedded microprocessor for automatic PF correction, phase-unbalance detection, and self-protection.    Compact &amp; Easy:\u00a0All-in-one design simplifies installation, wiring, and system expansion.    Enhanced Safety:\u00a0Internal fuses, over-temperature, and over-voltage protection ensure long operational life.    Real-Time Data:\u00a0LCD display shows PF, voltage, current, harmonics (THD), and status.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/swgct.net\/de\/produkt\/anti-harmonic-smart-capacitor\/\" \/>\n<meta property=\"og:site_name\" content=\"Swgct\" \/>\n<meta property=\"og:image\" content=\"https:\/\/swgct.net\/wp-content\/uploads\/2025\/12\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1707\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/\",\"url\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/\",\"name\":\"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids - Swgct\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/swgct.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/swgct.net\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png\",\"datePublished\":\"2025-12-05T07:09:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/#breadcrumb\"},\"inLanguage\":\"de-CH\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de-CH\",\"@id\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/#primaryimage\",\"url\":\"https:\\\/\\\/swgct.net\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png\",\"contentUrl\":\"https:\\\/\\\/swgct.net\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png\",\"width\":1707,\"height\":2560},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/swgct.net\\\/product\\\/anti-harmonic-smart-capacitor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/swgct.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product\",\"item\":\"https:\\\/\\\/swgct.net\\\/product\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/swgct.net\\\/#website\",\"url\":\"https:\\\/\\\/swgct.net\\\/\",\"name\":\"Swgct\",\"description\":\"Shenzhen WANGAO Complete Sets Of Equipment Co.,Ltd.is aprofessional enterprise engagedin distribution switch controlequipment,electrical complete equipment, low-voltage componentsand processing.\",\"publisher\":{\"@id\":\"https:\\\/\\\/swgct.net\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/swgct.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-CH\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/swgct.net\\\/#organization\",\"name\":\"Swgct\",\"url\":\"https:\\\/\\\/swgct.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-CH\",\"@id\":\"https:\\\/\\\/swgct.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/swgct.net\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/wechat_2025-08-25_103159_195-removebg-preview.png\",\"contentUrl\":\"https:\\\/\\\/swgct.net\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/wechat_2025-08-25_103159_195-removebg-preview.png\",\"width\":792,\"height\":315,\"caption\":\"Swgct\"},\"image\":{\"@id\":\"https:\\\/\\\/swgct.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids - Swgct","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/swgct.net\/de\/produkt\/anti-harmonic-smart-capacitor\/","og_locale":"de_DE","og_type":"article","og_title":"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids","og_description":"Our Anti-Harmonic Smart Capacitor is an advanced power correction device designed to operate reliably in harmonic-rich environments. It integrates a detuned reactor (e.g., 7% or 14% impedance) with an intelligent switching module, providing safe, automatic reactive power compensation while protecting itself from harmonic overloads. This all-in-one solution improves power factor, reduces energy losses, and ensures stable performance in industrial and commercial applications. Bullet Points:     Harmonic Immunity:\u00a0Built-in detuning reactor prevents resonance and protects capacitor from overheating due to harmonics.    Intelligent Control:\u00a0Embedded microprocessor for automatic PF correction, phase-unbalance detection, and self-protection.    Compact &amp; Easy:\u00a0All-in-one design simplifies installation, wiring, and system expansion.    Enhanced Safety:\u00a0Internal fuses, over-temperature, and over-voltage protection ensure long operational life.    Real-Time Data:\u00a0LCD display shows PF, voltage, current, harmonics (THD), and status.","og_url":"https:\/\/swgct.net\/de\/produkt\/anti-harmonic-smart-capacitor\/","og_site_name":"Swgct","og_image":[{"width":1707,"height":2560,"url":"https:\/\/swgct.net\/wp-content\/uploads\/2025\/12\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/","url":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/","name":"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids - Swgct","isPartOf":{"@id":"https:\/\/swgct.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/#primaryimage"},"image":{"@id":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/#primaryimage"},"thumbnailUrl":"https:\/\/swgct.net\/wp-content\/uploads\/2025\/12\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png","datePublished":"2025-12-05T07:09:40+00:00","breadcrumb":{"@id":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/#breadcrumb"},"inLanguage":"de-CH","potentialAction":[{"@type":"ReadAction","target":["https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/"]}]},{"@type":"ImageObject","inLanguage":"de-CH","@id":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/#primaryimage","url":"https:\/\/swgct.net\/wp-content\/uploads\/2025\/12\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png","contentUrl":"https:\/\/swgct.net\/wp-content\/uploads\/2025\/12\/\u6297\u8c10\u578b\u667a\u80fd\u7535\u5bb9\u5668-scaled.png","width":1707,"height":2560},{"@type":"BreadcrumbList","@id":"https:\/\/swgct.net\/product\/anti-harmonic-smart-capacitor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/swgct.net\/"},{"@type":"ListItem","position":2,"name":"Product","item":"https:\/\/swgct.net\/product\/"},{"@type":"ListItem","position":3,"name":"Anti-Harmonic Smart Capacitor \u2013 Reactive Power Compensation for Distorted Grids"}]},{"@type":"WebSite","@id":"https:\/\/swgct.net\/#website","url":"https:\/\/swgct.net\/","name":"Swgct","description":"Shenzhen WANGAO Complete Sets Of Equipment Co.,Ltd.is aprofessional enterprise engagedin distribution switch controlequipment,electrical complete equipment, low-voltage componentsand processing.","publisher":{"@id":"https:\/\/swgct.net\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/swgct.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-CH"},{"@type":"Organization","@id":"https:\/\/swgct.net\/#organization","name":"Swgct","url":"https:\/\/swgct.net\/","logo":{"@type":"ImageObject","inLanguage":"de-CH","@id":"https:\/\/swgct.net\/#\/schema\/logo\/image\/","url":"https:\/\/swgct.net\/wp-content\/uploads\/2025\/10\/wechat_2025-08-25_103159_195-removebg-preview.png","contentUrl":"https:\/\/swgct.net\/wp-content\/uploads\/2025\/10\/wechat_2025-08-25_103159_195-removebg-preview.png","width":792,"height":315,"caption":"Swgct"},"image":{"@id":"https:\/\/swgct.net\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product\/29456","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/comments?post=29456"}],"version-history":[{"count":1,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product\/29456\/revisions"}],"predecessor-version":[{"id":29463,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product\/29456\/revisions\/29463"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/media\/29458"}],"wp:attachment":[{"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/media?parent=29456"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product_brand?post=29456"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product_cat?post=29456"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/swgct.net\/de\/wp-json\/wp\/v2\/product_tag?post=29456"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}